Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Clin Nucl Med ; 20(1): 13-7, 1995 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7895428

RESUMO

Planar renal scintigraphy with Tc-99m DMSA has become established as a standard diagnostic test to determine if a kidney has been scarred by infection. It has been suggested that high resolution SPECT may improve the sensitivity of detection of renal scars. To determine if it is possible to produce good quality renal SPECT with a short acquisition time, 10 adults were examined with a new multi-detector gamma camera using 8 minute, 16 minute, and 32 minute acquisitions. The number of defects seen (N = 16) with an 8 minute acquisition was not significantly different from the defects (N = 15) seen using a 16 minute and a 32 minute acquisition. In adults when imaging with a multi-detector gamma camera there was no clinical advantage in using an acquisition of longer than 8 minutes.


Assuntos
Câmaras gama , Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Compostos de Organotecnécio , Succímero , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Adulto , Feminino , Humanos , Nefropatias/etiologia , Masculino , Pessoa de Meia-Idade , Ácido Dimercaptossuccínico Tecnécio Tc 99m , Infecções Urinárias/complicações , Infecções Urinárias/diagnóstico por imagem
2.
Nucl Med Commun ; 15(8): 643-52, 1994 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7970446

RESUMO

The clinical experience with the Toshiba GCA-9300A single photon emission tomography (SPET) system is discussed along with typical acquisition protocols for various SPET studies. The system was used to perform SPET studies in normals and in a variety of brain and body disorders. Its three Anger-type gamma cameras forming a triangular aperture offer a substantial increase in sensitivity compared to a single rotating gamma camera. This has allowed the routine use of lead fanbeam super high-resolution collimators (SHR FB) for 99Tcm-hexamethylpropyleneamine oxime (HMPAO) brain SPET studies and high-resolution parallel-hole collimators (HR PH) for cardiac and other body studies. The resulting improvement in spatial resolution coupled with the ease of patient positioning and the greater patient throughput compared to a conventional tomographic gamma camera, will enhance the role of brain and body SPET for both routine and research purposes.


Assuntos
Encefalopatias/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Dor no Peito/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Osso e Ossos/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio , Oximas , Valores de Referência , Sensibilidade e Especificidade , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
J Nucl Med ; 34(10): 1778-89, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8410298

RESUMO

The physical performance of the Toshiba GCA-9300A triple-headed SPECT system has been assessed. Using a water-filled cylinder containing 99mTc, the tomographic volume sensitivity was 33.8 and 34.8 kcps/(MBq/ml)/cm for the high-resolution, parallel-hole (HR-PH) collimator and the super high-resolution, lead fanbeam (SHR-FB) collimator, respectively, excluding the rotation time(s) during scanning when data are not acquired. The tomographic spatial resolution at the center, in air, with 132 mm radius of rotation was 10.2 and 7.8 mm FWHM with the HR-PH and SHR-FB collimators, respectively; in water it was 11.0 and 7.8 mm. Reconstructed relative activity concentrations were accurate for both collimator sets if attenuation correction was used. With the SHR-FB collimators, the average peak-to-valley ratio of five-line sources in water improved significantly when an asymmetric energy window was used. Using the three-dimensional Hoffman brain phantom which simulates a 4:1 grey matter-to-white matter ratio and the usual choice of acquisition and processing parameters for brain studies, the reconstructed grey matter-to-white matter ratio was only about 1.7 for total counts typically acquired in a 99mTc-HMPAO study (4.0 M counts) and only 2.3 for 40 M counts. There was a qualitative improvement with an asymmetric energy window.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Encéfalo/diagnóstico por imagem , Estudos de Avaliação como Assunto , Humanos , Modelos Estruturais
4.
Br J Radiol ; 66(789): 817-22, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8220955

RESUMO

Planar skeletal scintigraphy has become established as a standard diagnostic test performed within the nuclear medicine department. Since the 1970s good quality images have been produced using an Anger gamma camera and 99Tcm-labelled diphosphonates. Single photon emission tomography (SPET) has improved the sensitivity of detection and the ability to localize bony pathology, particularly benign bone disease in the spine. Recently multi-detector gamma cameras dedicated to SPET have become available. One such system, the Toshiba GCA-9300A, has been used to perform routine clinical skeletal SPET in 81 patients. Good quality images have been obtained using an 8 min acquisition in the axial skeleton and a 16 min acquisition protocol in the peripheral skeleton. Multiple sites can be tomographed in the same patient during the same examination using two or more 8 min acquisitions. Such a multi-detector gamma camera offers advantages over the standard single-headed rotating camera for skeletal SPET in terms of both imaging time and image quality. A cost analysis was performed which demonstrated that the additional cost of purchasing such a multidector gamma camera was less than 30.00 pounds per SPET study.


Assuntos
Osso e Ossos/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Neoplasias Ósseas/diagnóstico por imagem , Análise Custo-Benefício , Fêmur/diagnóstico por imagem , Pé/diagnóstico por imagem , Câmaras gama , Humanos , Articulação do Joelho/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Tórax/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/economia
5.
Nucl Med Commun ; 14(8): 628-33, 1993 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8371888

RESUMO

Single photon emission computed tomography (SPECT) with the tracer 99Tcm-hexamethylpropyleneamine oxime (HMPAO) provides images allowing semiquantitative estimation of regional cerebral blood flow (rCBF). Despite its widespread use there is little data on patterns of rCBF obtained using this tracer in normal elderly subjects, although other methods of measurement suggest a fall in cerebral blood flow with age. Furthermore, the detection of interhemispheric asymmetries on HMPAO SPECT is often used to identify areas of pathological abnormality yet there is little data on the prevalence of asymmetries in the normal elderly. An increased prevalence of asymmetries in the elderly may explain the difficulties recently reported in using functional imaging in the diagnosis of Alzheimer's dementia. Patterns of HMPAO uptake were compared in 10 young (mean age 24.9 years; range 21-34 years) and 10 elderly (mean age 74.1 years; range 70-76 years) normal subjects. Percentage interhemispheric asymmetry ratios were calculated and found to be greater in the elderly, particularly for the temporal cortex (young 0.87%, elderly 3.73%, P < 0.001). The proportion of injected HMPAO taken up by the head was 29% higher in the younger age group. Analysis of regional uptake revealed that this trend towards reduced uptake in the elderly was a global phenomenon affecting all brain regions. The increased interhemispheric asymmetries seen in the elderly imply that a higher threshold for interpreting asymmetries as abnormal must be used in the elderly, particularly for the temporal cortex.


Assuntos
Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Compostos de Organotecnécio , Oximas , Adulto , Idoso , Feminino , Humanos , Masculino , Valores de Referência , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada de Emissão de Fóton Único
6.
Nucl Med Commun ; 13(9): 648-55, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1448237

RESUMO

Dual gated (DG) cardiac single photon emission computed tomographic (SPECT) studies at end-diastole (ED) and end-systole (ES) were acquired in 27 ischaemic heart disease (IHD) patients after intravenous injection of 555-740 MBq 99Tcm-MIBI. Acquisition parameters were: 180 degrees from LPO to RAO, 32 projections, 64 x 64 matrix, 75 cardiac beats per projection, 80 ms at ED and 80 ms at ES for each cardiac cycle. A computer program was developed to calculate the ED and ES left ventricular (LV) volumes and LV ejection fraction (EF). The computational approach is interactive, semi-automatic and iterative with built-in visual quality control. Short axis slices are used with corresponding ED and ES slices processed as pairs from apex to base. Left ventricular cavity pixels are identified and summed on a slice-by-slice basis. Myocardial pixels are similarly identified. The computed LVEF and ED and ES volumes have been correlated with those from contrast ventriculography (CV). The mean calculated EF for 27 patients was 53.6 +/- 10.7% from DG SPECT versus 55.3 +/- 12.1% from CV (NS). The EF linear correlation coefficient was r = 0.97.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Isquemia Miocárdica/fisiopatologia , Nitrilas , Compostos de Organotecnécio , Volume Sistólico/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Isquemia Miocárdica/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi
7.
J Neurol ; 239(7): 363-6, 1992 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1403016

RESUMO

Conventional imaging with computed tomography (CT) and magnetic resonance imaging (MRI) may show abnormalities in central nervous system Behcet's syndrome but is normal in some cases. Recently in two cases positron emission tomography has shown abnormalities in blood flow and glucose metabolism far more extensive than the abnormalities seen on CT and MRI scans in the same patients. We report a patient with neuro-Behcet's syndrome presenting with headache and personality change in whom CT and MRI brain imaging was normal, but regional cerebral blood flow imaging using single photon emission tomography with the tracer HMPAO showed extensive perfusion deficits which partially reversed after 3 months of prednisolone therapy. This technique may aid the diagnosis of cerebral involvement in Behcet's syndrome, although the cause and incidence of the perfusion deficits need further evaluation.


Assuntos
Síndrome de Behçet/diagnóstico , Circulação Cerebrovascular , Tomografia Computadorizada de Emissão de Fóton Único , Síndrome de Behçet/tratamento farmacológico , Síndrome de Behçet/metabolismo , Glucose/metabolismo , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio , Oximas , Prednisolona/uso terapêutico , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada por Raios X
8.
J Nerv Ment Dis ; 180(7): 413-7, 1992 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1624921

RESUMO

Structural brain abnormalities have recently been discovered using magnetic resonance imaging in infantile autism, a neurodevelopmental disorder of unknown etiology. However, functional neuroimaging studies in autism using positron emission tomography have had conflicting results and have not explained how the known structural brain abnormalities in autism act in a functioning brain to produce autistic behavior. Using a new technology, high-resolution brain single photon emission tomography, we studied and scanned four young adults with infantile autism and four age-matched controls using the labeled ligand 99mTc-D,L-hexamethyl-propylene amine oxime (99mTc-HMPAO). Total brain perfusion was significantly decreased in autism subjects (range, 58% to 72% of controls, p less than or equal to .02). In addition to the globally decreased perfusion, the autism group also had regionally decreased flow in the right lateral temporal and right, left, and midfrontal lobes compared with controls (p less than or equal to .02, Mann-Whitney t-test).


Assuntos
Transtorno Autístico/fisiopatologia , Circulação Cerebrovascular , Adulto , Transtorno Autístico/diagnóstico por imagem , Feminino , Lobo Frontal/irrigação sanguínea , Lobo Frontal/diagnóstico por imagem , Humanos , Masculino , Compostos de Organotecnécio , Oximas , Projetos Piloto , Tecnécio Tc 99m Exametazima , Lobo Temporal/irrigação sanguínea , Lobo Temporal/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
10.
Eur J Nucl Med ; 19(4): 236-42, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1597238

RESUMO

The GE/CGR Neurocam is a triple-headed single photon emission tomography (SPET) system dedicated to multi-slice brain tomography. We have assessed its physical performance in terms of sensitivity and resolution, and its clinical efficacy in comparison with a modern, single rotating gamma-camera (GE 400XCT). Using a water-filled cylinder containing technetium-99m, the tomographic volume sensitivity of the Neurocam was 30.0 and 50.7 kcps/MBq.ml.cm for the high-resolution (HR) and general-purpose (GP) collimators, respectively; the corresponding values for the single rotating camera were 7.6 and 12.8 kcps/(MBq/ml)/cm. Tomographic resolution was measured in air and in water. In air, the Neurocam resolution at the cente of the field-of-view (FOV) is 9.0 and 10.7 mm full width at half-maximum (FWHM) with the HR and GP collimators, respectively, and is isotropic in the three orthogonal planes; the resolution of the GE 400XCT with 13 cm radius of rotation is 10.3 and 11.7 mm, respectively. For the Neurocam with the HR collimator, the transaxial FWHM values in water were 9.7 mm at the centre and 9.5 mm radial (6.6 mm tangential) at 8 cm from the centre. The physical characteristics of the Neurocam enable the routine acquisition of brain perfusion data with technetium-99m hexamethyl-propylene amine oxime (99mTc-HMPAO) in about 14 min, yielding better image quality than with a single rotating camera in 40 min.


Assuntos
Encéfalo/diagnóstico por imagem , Demência por Múltiplos Infartos/diagnóstico por imagem , Câmaras gama , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Estudos de Avaliação como Assunto , Humanos , Compostos de Organotecnécio , Oximas , Tecnécio Tc 99m Exametazima
11.
IEEE Trans Med Imaging ; 11(1): 2-8, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-18218350

RESUMO

Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is equal to the energy in the difference between the distorted and blurred images. The approach is based on the Lagrange multiplier method. The first algorithm reduces the problem to the computation of few discrete Fourier transforms and allows control of the degree of sharpness and smoothness of the restored image. The second algorithm with weight matrices included allows the handling of edges and flat regions in the image in a pleasing manner for the human visual system. In this case the iterative conjugate gradient method is used in conjunction with the discrete Fourier transform to minimize the Lagrangian function. The application of these algorithms to nuclear medicine images is presented.

12.
Eur J Nucl Med ; 19(2): 138-50, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1563442

RESUMO

We discuss recent trends in collimator design and technology, with emphasis on theoretical and practical issues of importance for single photon emission tomography (SPET). The well-known imaging performance parameters of parallel-hole collimators are compared with those of fan-beam collimators, which have enjoyed considerable success in recent years, particularly for brain SPET. We review a simplistic approach to the collimator optimization problem, as well as more sophisticated "task-dependent" treatments and important considerations for SPET collimator design. Practical guidance is offered for understanding trade-offs that must be considered for clinical imaging. Finally, selective comparisons among different SPET systems and collimators are presented for illustrative purposes.


Assuntos
Tecnologia Radiológica/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Desenho de Equipamento , Câmaras gama , Humanos , Variações Dependentes do Observador
13.
J Neural Transm Gen Sect ; 87(3): 231-6, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1581020

RESUMO

Recent advances in single photon emission computed tomography (SPECT) have allowed improved image resolution with lower doses of labelled tracer. Capitalizing on these improvements, the authors have developed a new SPECT protocol for imaging neuronal activation. We outline this technique and describe how it can demonstrate increased human motor cortex activity in normal subjects performing a motor task. The ability to accurately demonstrate neuronal activation with SPECT using this method may have important scientific and clinical implications.


Assuntos
Córtex Motor/fisiologia , Adulto , Idoso , Feminino , Dedos/inervação , Dedos/fisiologia , Lateralidade Funcional , Humanos , Masculino , Pessoa de Meia-Idade , Córtex Motor/diagnóstico por imagem , Compostos de Organotecnécio , Oximas , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada de Emissão , Tomografia Computadorizada de Emissão de Fóton Único
14.
Nucl Med Commun ; 12(12): 1025-30, 1991 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1811197

RESUMO

The aim of this study was to investigate whether in the distal, poorly perfused part of a flap the pressure gradient remains sufficient to allow flow of plasma and red blood cells (RBCs) within the first hour after flap elevation. For this purpose 99Tcm-labelled RBCs and 111In-chloride-labelled plasma proteins in an arterial skin flap that extended beyond the boundaries of its vascular territory in sheep has been used. Flow information was derived for both plasma and RBCs from dynamic acquisitions, while volume information was derived from dual energy static acquisition at equilibrium (steady-state). Results indicate that the mean flow and the mean volume of plasma are equal through the entire length of the flap. Although the flow is minimal, there is no stasis of plasma in the poorly perfused part of the flap. By comparing the mean flow of RBCs to their mean volume, no difference is seen in the well-perfused proximal two-thirds of the flap. In the distal, poorly perfused part, flow decreases while the volume increases. The increased volume of RBCs at minimal flow indicate pooling of RBCs in this region already in the first hour after flap elevation.


Assuntos
Artérias/cirurgia , Eritrócitos/fisiologia , Plasma/fisiologia , Retalhos Cirúrgicos , Animais , Artérias/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Volume de Eritrócitos , Eritrócitos/diagnóstico por imagem , Índio , Radioisótopos de Índio , Masculino , Plasma/citologia , Volume Plasmático , Cintilografia , Ovinos , Tecnécio
15.
Am J Physiol Imaging ; 6(4): 183-9, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1817571

RESUMO

A VAX-based Lexidata image processing station has been used for the development and application of image processing and data analysis techniques in nuclear medicine. Within the area of cardiac multigated equilibrium blood-pool scintigraphy, the computational implementation of the T4/5 functional image, a new left ventricular functional image, is presented. This image reflects myocardial compliance. The versatility of the implementation is demonstrated. Examples of the T4/5 functional image are presented. The VAX-based Lexidata image processing station is a useful tool for parameter, feature, and image extraction from nuclear medicine images.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Minicomputadores , Função Ventricular Esquerda/fisiologia , Doença das Coronárias/diagnóstico por imagem , Aneurisma Cardíaco/diagnóstico por imagem , Humanos , Valores de Referência
16.
Am J Physiol Imaging ; 6(3): 121-8, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1772693

RESUMO

Selection of patients with chronic bilharzial uropathy (CBU) for surgery is a difficult problem due to the presence of grossly dilated urinary tracts without a significant obstruction in most of the cases. In this prospective study of 40 patients with CBU, the time-activity curve (TAC) patterns of the pre- and postoperative Tc-99m DTPA diuretic renography (RDR) studies were compared with the corresponding parenchymal transit time indices (PTTI). The aims were to find out which of these renographic parameters was more accurate in identifying obstruction and which was better in predicting the outcome of surgery. PTTI was more sensitive than TAC in identifying obstruction (96% and 92%, respectively) but it was less specific (78% and 98%). The detection accuracy of RDR for obstruction using TAC patterns was 96% compared to 84% using PTTI. Being independent of renal uptake function, PTTI could not predict the outcome of surgery as TAC could. In contrast to PTTI, TAC patterns could differentiate obstructed kidneys from severely nephropathic kidneys. However, PTTI was useful in identifying kidneys with residual nephropathy.


Assuntos
Renografia por Radioisótopo , Esquistossomose Urinária/diagnóstico por imagem , Pentetato de Tecnécio Tc 99m , Obstrução Ureteral/diagnóstico por imagem , Obstrução Ureteral/cirurgia , Adulto , Doença Crônica , Previsões/métodos , Furosemida , Humanos , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Renografia por Radioisótopo/métodos , Sensibilidade e Especificidade , Fatores de Tempo , Resultado do Tratamento , Obstrução Ureteral/parasitologia
17.
Artigo em Inglês | MEDLINE | ID: mdl-1828908

RESUMO

This study evaluates the effect of the new combined thromboxane synthesis inhibitor and receptor blocker, ridogrel, on the circulation of arterial skin flaps in sheep. Sixteen flaps, 8 controls and 8 treated with 5 mg/kg ridogrel, were investigated using 111Indium chloride labelled plasma and 99mTc labelled red blood cells (RBCs). Dynamic imaging was performed after a bolus injection using a GE 400 AT gamma camera. For each flap quantitative analysis of plasma and RBC flow was based on time activity curves obtained from 12 regions of interest. Analysis of flow data was made immediately after flap elevation and three hours later. Both plasma and RBC flows declined after 3 hours. Treatment with ridogrel significantly prevented deterioration of perfusion by increasing plasma and RBC flow mostly in the distal, ischaemic regions of the flap where stasis was evident in the control flaps.


Assuntos
Ácidos Pentanoicos/farmacologia , Piridinas/farmacologia , Pele/irrigação sanguínea , Retalhos Cirúrgicos , Tromboxano-A Sintase/antagonistas & inibidores , Animais , Eritrócitos/efeitos dos fármacos , Eritrócitos/fisiologia , Radioisótopos de Índio , Masculino , Plasma/efeitos dos fármacos , Plasma/fisiologia , Receptores de Prostaglandina/efeitos dos fármacos , Receptores de Tromboxanos , Fluxo Sanguíneo Regional/efeitos dos fármacos , Ovinos , Tecnécio
18.
J Reconstr Microsurg ; 6(4): 345-51, 1990 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2148602

RESUMO

The aim of the study was experimentally to evaluate the capability and reliability of laser Doppler flowmetry (LDF) in conditions of circulatory deficiency, by correlating it to flow-related parameters measured by a radionuclide-imaging technique and using 99m-Tc red blood cells (RBCs). For this purpose, a pedicle island flap in the sheep was used, with well-perfused proximal parts and with evident stasis in the distal third of the flap. No correlation was found between results obtained with the two techniques. In regions with evident stasis, falsely high LDF readings were recorded. This may be due to a back-and-forth motion of the RBCs under the probe, rather than to true flow. It was concluded that, while LDF seems reliable in detecting complete arterial occlusion, it is unreliable in predicting either complete venous occlusion or partial obstruction of the flow to and from the flap. Clinical use for this purpose cannot be recommended.


Assuntos
Pele/irrigação sanguínea , Retalhos Cirúrgicos , Animais , Capilares/fisiologia , Procedimentos Cirúrgicos Dermatológicos , Eritrócitos , Lasers , Masculino , Microcirculação , Angiografia Cintilográfica , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Reologia , Ovinos , Pele/diagnóstico por imagem , Tecnécio , Fatores de Tempo
19.
Br J Urol ; 66(2): 137-43, 1990 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-2117983

RESUMO

The selection of patients with chronic obstructive uropathy for surgery is difficult because of problems in identifying true obstruction in a grossly dilated urinary tract. This is especially so in schistosomal (bilharzial) obstructive uropathy. A prospective study of 90 patients (68 with chronic schistosomal and 22 with non-bilharzial obstructive uropathy) was carried out. All patients underwent pre-operative and post-operative radionuclide 99mTc DTPA diuretic renography (RDR). The aims were to assess the value of RDR in the pre- and post-operative management of these patients and whether it could predict the outcome of surgery. Distinctive renogram patterns were identified in patients who required surgical management. These were found useful in monitoring the results and in predicting the outcome of surgery.


Assuntos
Compostos de Organotecnécio , Ácido Pentético , Cuidados Pré-Operatórios , Renografia por Radioisótopo , Esquistossomose Urinária/complicações , Obstrução Ureteral/diagnóstico por imagem , Humanos , Período Pós-Operatório , Valor Preditivo dos Testes , Estudos Prospectivos , Pentetato de Tecnécio Tc 99m , Obstrução Ureteral/etiologia , Obstrução Ureteral/cirurgia
20.
Nucl Med Commun ; 11(2): 95-101, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2356071

RESUMO

Deciding on the action level for gamma camera non-uniformity is difficult because the reproducibilities of quality control measurements and service adjustments are usually unknown. This work evaluated the reproducibilities of integral uniformity (IU), differential uniformity (DU) and the corrected relative standard deviation (CRSD). The latter was calculated by removing from the relative standard deviation of the pixel counts the component due to statistical fluctuations. The reproducibility of each parameter was evaluated by analysing 10 intrinsic flood acquisitions with total counts of 2, 5, 10 and 30 million. All three parameters were less reproducible at the lower count densities, but as expected IU and DU also showed higher mean values. CRSD was consistent and highly reproducible, at all count densities. At 10 million counts CRSD had a coefficient of variation (COV) of 1.3% which was a five-fold improvement over the 6.6% and 6.1% found for IU and DU, respectively. The relative sensitivity of IU, DU and CRSD was compared in monthly measurements on 10 gamma cameras over one year. No significant difference in relative sensitivity was demonstrated: a change in camera performance produced about the same percentage change in each parameter. The precision with which service engineers adjust gamma cameras was also assessed by measuring the uniformity of 10 gamma cameras immediately after service adjustment at monthly intervals over one year. Finally, general action levels were defined for IU, DU and CRSD at 7%, 5% and 2.5% respectively.


Assuntos
Câmaras gama/normas , Controle de Qualidade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA